514 research outputs found

    Pain management in hospitals: patients’ satisfaction and related barriers

    Get PDF
    Background: Suboptimal pain control has been frequently reported in healthcare settings and documented to negatively impact patients’ health. Patients’ perception regarding pain management may influence their satisfaction regarding treatment. Objectives: This study focuses on the assessment of patients’ satisfaction regarding pain therapy and defining patient-related barriers for its implication. Methods: A cross-sectional study was conducted in two tertiary care hospitals from April till July 2017. A face-to face interview questionnaire was filled regarding pain scores and patients’ attitudes regarding pain management. Both medical and post-surgical adult patients with all types of pain were eligible to participate. A descriptive analysis of patient satisfaction and perceptions regarding pain management was done. Results: Results from 183 participants with a mean age of 49 (SD=17.33) revealed that pain was their main reason for hospitalization (71.6% of the cases). Numeric pain scores were recorded only in 14.2% of the patient medical files. Pain intensity documentation by healthcare professionals was found in 41.5% of the cases, and 7.7% of the patients had to wait for more than 30 minutes before getting the pain medication. Around 85% of the patients were satisfied with their pain management. Patients’ barriers to effective pain therapy were mainly fear of adverse effects, addiction, and additional costs (p<0.05). Conclusions: Pain remains a prevalent problem that requires more efforts for improvement. Our study can effectively serve as a start for larger studies where barriers to pain management can be assessed as an independent variable affecting pain management practice

    Recent and future trends in synthetic greenhouse gas radiative forcing

    Get PDF
    Atmospheric measurements show that emissions of hydrofluorocarbons (HFCs) and hydrochlorofluorocarbons are now the primary drivers of the positive growth in synthetic greenhouse gas (SGHG) radiative forcing. We infer recent SGHG emissions and examine the impact of future emissions scenarios, with a particular focus on proposals to reduce HFC use under the Montreal Protocol. If these proposals are implemented, overall SGHG radiative forcing could peak at around 355 mW m[superscript −2] in 2020, before declining by approximately 26% by 2050, despite continued growth of fully fluorinated greenhouse gas emissions. Compared to “no HFC policy” projections, this amounts to a reduction in radiative forcing of between 50 and 240 mW m[superscript −2] by 2050 or a cumulative emissions saving equivalent to 0.5 to 2.8 years of CO2 emissions at current levels. However, more complete reporting of global HFC emissions is required, as less than half of global emissions are currently accounted for.Natural Environment Research Council (Great Britain) (Advanced Research Fellowship NE/I021365/1)United States. National Aeronautics and Space Administration (Upper Atmospheric Research Program Grant NNX11AF17G)United States. National Oceanic and Atmospheric Administratio

    Characterization of uncertainties in atmospheric trace gas inversions using hierarchical Bayesian methods

    Get PDF
    We present a hierarchical Bayesian method for atmospheric trace gas inversions. This method is used to estimate emissions of trace gases as well as "hyper-parameters" that characterize the probability density functions (PDFs) of the a priori emissions and model-measurement covariances. By exploring the space of "uncertainties in uncertainties", we show that the hierarchical method results in a more complete estimation of emissions and their uncertainties than traditional Bayesian inversions, which rely heavily on expert judgment. We present an analysis that shows the effect of including hyper-parameters, which are themselves informed by the data, and show that this method can serve to reduce the effect of errors in assumptions made about the a priori emissions and model-measurement uncertainties. We then apply this method to the estimation of sulfur hexafluoride (SF6) emissions over 2012 for the regions surrounding four Advanced Global Atmospheric Gases Experiment (AGAGE) stations. We find that improper accounting of model representation uncertainties, in particular, can lead to the derivation of emissions and associated uncertainties that are unrealistic and show that those derived using the hierarchical method are likely to be more representative of the true uncertainties in the system. We demonstrate through this SF6 case study that this method is less sensitive to outliers in the data and to subjective assumptions about a priori emissions and model-measurement uncertainties than traditional methods

    Upper critical field divergence induced by mesoscopic phase separation in the organic superconductor (TMTSF)2ReO4

    Full text link
    Due to the competition of two anion orders, (TMTSF)2ReO4, presents a phase coexistence between semiconducting and metallic (superconducting) regions (filaments or droplets) in a wide range of pressure. In this regime, the superconducting upper critical field for H parallel to both c* and b' axes present a linear part at low fields followed by a divergence above a cross-over field. This cross-over corresponds to the 3D-2D decoupling transition expected in filamentary or granular superconductors. The sharpness of the transition also demonstrates that all filaments are of similar sizes and self organize in a very ordered way. The distance between the filaments and their cross-section are estimated.Comment: 4 pages, 4 figure

    Greenhouse gas measurements from a UK network of tall towers: technical description and first results

    Get PDF
    A network of three tall tower measurement stations was set up in 2012 across the United Kingdom to expand measurements made at the long-term background northern hemispheric site, Mace Head, Ireland. Reliable and precise in situ greenhouse gas (GHG) analysis systems were developed and deployed at three sites in the UK with automated instrumentation measuring a suite of GHGs. The UK Deriving Emissions linked to Climate Change (UK DECC) network uses tall (165–230 m) open-lattice telecommunications towers, which provide a convenient platform for boundary layer trace gas sampling. In this paper we describe the automated measurement system and first results from the UK DECC network for CO2, CH4, N2O, SF6, CO and H2. CO2 and CH4 are measured at all of the UK DECC sites by cavity ring-down spectroscopy (CRDS) with multiple inlet heights at two of the three tall tower sites to assess for boundary layer stratification. The short-term precisions (1σ on 1 min means) of CRDS measurements at background mole fractions for January 2012 to September 2015 is < 0.05 µmol mol−1 for CO2 and < 0.3 nmol mol−1 for CH4. Repeatability of standard injections (1σ) is < 0.03 µmol mol−1 for CO2 and < 0.3 nmol mol−1 for CH4 for the same time period. N2O and SF6 are measured at three of the sites, and CO and H2 measurements are made at two of the sites, from a single inlet height using gas chromatography (GC) with an electron capture detector (ECD), flame ionisation detector (FID) or reduction gas analyser (RGA). Repeatability of individual injections (1σ) on GC and RGA instruments between January 2012 and September 2015 for CH4, N2O, SF6, CO and H2 measurements were < 2.8 nmol mol−1, < 0.4 nmol mol−1, < 0.07 pmol mol−1, < 2 nmol mol−1 and < 3 nmol mol−1, respectively. Instrumentation in the network is fully automated and includes sensors for measuring a variety of instrumental parameters such as flow, pressures, and sampling temperatures. Automated alerts are generated and emailed to site operators when instrumental parameters are not within defined set ranges. Automated instrument shutdowns occur for critical errors such as carrier gas flow rate deviations. Results from the network give good spatial and temporal coverage of atmospheric mixing ratios within the UK since early 2012. Results also show that all measured GHGs are increasing in mole fraction over the selected reporting period and, except for SF6, exhibit a seasonal trend. CO2 and CH4 also show strong diurnal cycles, with night-time maxima and daytime minima in mole fractions

    The variability of methane, nitrous oxide and sulfur hexafluoride in Northeast India

    Get PDF
    High-frequency atmospheric measurements of methane (CH[subscript 4]), nitrous oxide (N[subscript 2]O) and sulfur hexafluoride (SF[subscript 6]) from Darjeeling, India are presented from December 2011 (CH[subscript 4])/March 2012 (N[subscript 2]O and SF[subscript 6]) through February 2013. These measurements were made on a gas chromatograph equipped with a flame ionization detector and electron capture detector, and were calibrated on the Tohoku University, the Scripps Institution of Oceanography (SIO)-98 and SIO-2005 scales for CH[subscript 4], N[subscript 2]O and SF[subscript 6], respectively. The observations show large variability and frequent pollution events in CH[subscript 4] and N[subscript 2]O mole fractions, suggesting significant sources in the regions sampled by Darjeeling throughout the year. By contrast, SF[subscript 6] mole fractions show little variability and only occasional pollution episodes, likely due to weak sources in the region. Simulations using the Numerical Atmospheric dispersion Modelling Environment (NAME) particle dispersion model suggest that many of the enhancements in the three gases result from the transport of pollutants from the densely populated Indo-Gangetic Plains of India to Darjeeling. The meteorology of the region varies considerably throughout the year from Himalayan flows in the winter to the strong south Asian summer monsoon. The model is consistent in simulating a diurnal cycle in CH[subscript 4] and N[subscript 2]O mole fractions that is present during the winter but absent in the summer and suggests that the signals measured at Darjeeling are dominated by large-scale (~100 km) flows rather than local (<10 km) flows.Massachusetts Institute of Technology. Center for Global Change Science (Director's Fund)Massachusetts Institute of Technology. Joint Program on the Science & Policy of Global ChangeMartin Family Society of Fellows for SustainabilityMIT Energy InitiativeMIT International Science and Technology InitiativeUnited States. National Aeronautics and Space Administration (Grant NNX11AF17G)United States. National Oceanic and Atmospheric Administration (Contract RA133R09CN0062

    Survey instruments used in clinical and epidemiological research on waterpipe tobacco smoking: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The primary objective was to systematically review the medical literature for instruments validated for use in epidemiological and clinical research on waterpipe smoking.</p> <p>Methods</p> <p>We searched the following databases: MEDLINE, EMBASE, and ISI the Web of Science. We selected studies using a two-stage duplicate and independent screening process. We included papers reporting on the development and/or validation of survey instruments to measure waterpipe tobacco consumption or related concepts. Two reviewers used a standardized and pilot tested data abstraction form to collect data from each eligible study using a duplicate and independent screening process. We also determined the percentage of observational studies assessing the health effects of waterpipe tobacco smoking and the percentage of studies of prevalence of waterpipe tobacco smoking that have used validated survey instruments.</p> <p>Results</p> <p>We identified a total of five survey instruments. One instrument was designed to measure knowledge, attitudes, and waterpipe use among pregnant women and was shown to have internal consistency and content validity. Three instruments were designed to measure waterpipe tobacco consumption, two of which were reported to have face validity. The fifth instrument was designed to measure waterpipe dependence and was rigorously developed and validated. One of the studies of prevalence and none of the studies of health effects of waterpipe smoking used validated instruments.</p> <p>Conclusions</p> <p>A number of instruments for measuring the use of and dependence on waterpipe smoking exist. Future research should study content validity and cross cultural adaptation of these instruments.</p

    Evidence of a recent decline in UK emissions of hydrofluorocarbons determined by the InTEM inverse model and atmospheric measurements

    Get PDF
    National greenhouse gas inventories (GHGIs) are submitted annually to the United Nations Framework Convention on Climate Change (UNFCCC). They are estimated in compliance with Intergovernmental Panel on Climate Change (IPCC) methodological guidance using activity data, emission factors and facility-level measurements. For some sources, the outputs from these calculations are very uncertain. Inverse modelling techniques that use high-quality, long-term measurements of atmospheric gases have been developed to provide independent verification of national GHGIs. This is considered good practice by the IPCC as it helps national inventory compilers to verify reported emissions and to reduce emission uncertainty. Emission estimates from the InTEM (Inversion Technique for Emission Modelling) model are presented for the UK for the hydrofluorocarbons (HFCs) reported to the UNFCCC (HFC-125, HFC-134a, HFC-143a, HFC-152a, HFC-23, HFC-32, HFC-227ea, HFC-245fa, HFC-43-10mee and HFC-365mfc). These HFCs have high global warming potentials (GWPs), and the global background mole fractions of all but two are increasing, thus highlighting their relevance to the climate and a need for increasing the accuracy of emission estimation for regulatory purposes. This study presents evidence that the long-term annual increase in growth of HFC-134a has stopped and is now decreasing. For HFC-32 there is an early indication, its rapid global growth period has ended, and there is evidence that the annual increase in global growth for HFC-125 has slowed from 2018. The inverse modelling results indicate that the UK implementation of European Union regulation of HFC emissions has been successful in initiating a decline in UK emissions from 2018. Comparison of the total InTEM UK HFC emissions in 2020 with the average from 2009–2012 shows a drop of 35 %, indicating progress toward the target of a 79 % decrease in sales by 2030. The total InTEM HFC emission estimates (2008–2018) are on average 73 (62–83) % of, or 4.3 (2.7–5.9) Tg CO2-eq yr−1 lower than, the total HFC emission estimates from the UK GHGI. There are also significant discrepancies between the two estimates for the individual HFCs.</p
    corecore